This FULLRANGE lens offers a unique optical design for a clear and functional vision at all distances. FULLRANGE is manufactured by a patented lathe allowing the refractive rings to be as nitid as possible.
This INTENSITY lens offers a unique penta-focal technology, assembled in an optical design of symmetrical order. Unlike the conventional diffractive optical design, the intermediate lens is in the order 0, the distant one is in -2 and the near one is in +2, giving a much better intermediate vision.
This SeeLensAF is an aspherical lens. The optical design is oriented to minimize all the aberrations, including the spherical one of the cornea and maximize the modulation transference function of the intra-ocular lens. SeeLensAF improves the functional vision, offers an excellent quality vision in day and night conditions.
Intensity is the first lens with a symmetric distribution of focus around the order 0.
The exterior ring of the iris in the Canabrava Ring is a semi-circular ring designed to dilate and hold momentarily the iris in a secure manner, to ease the visual field of the surgeon and improve access to the crystalline in ophthalmologic surgeries.
The Ferrara Ring is an implant medical device to be placed in the corneal stroma to regularize corneal deformations caused by tissue pathologies and correction mistakes by associated refractions.
The Symblepharon Ring is used to treat total or partial adhesion between the internal face of the lid and the ocular globe as consequence of a scar, for example, chronic inflammation of the lids (blepharitis), eye trauma, thermal or chemical burns of the conjunctiva, infections like trachoma or surgical interventions of the eye.
The Capsular Tension Rings were designed to be inserted in the capsular bag at any time during a cataract surgery aiming to relax it equatorially, and also stabilize.
The Perforated Conformer is used to achieve a separation between the tarsal and bulbar conjunctiva. Made from medical grade acrylic in sizes small, medium and large. It has a concave shape with two holes to help with ocular drainage and drop administration.
Download InformationThe Ocular Shield is designed to protect the eyeball, specially, in palpebral surgery or in a DCR (dacryocystorhinostomy).
Download Information
The Palpebral Gold or Platinum Implants are designed to treat lagofthalmos functional defects. The design of the gold weights substitute in a orthostatic position the paralyzed orbicular function.
The AJL CELL 2% is as an used in surgical procedures of the anterior segment of the eye, including cataract. It protects the tissues and avoids corneal endothelium trauma and other ocular tissues.
The AJL BLUE 0.06% is an intraocular, biocompatible, trypan blue, sterile ophthalmic solution used in ophthalmic surgeries of the anterior segment. This ophthalmic dye is used as an aid in the capsulorhexis and minimizes the risk of eye tearing with mature cataracts with poor reflex in the eye fundus or small pupils.
The Glaucoma Implant Esnoper Clip is indicated for a non-penetrating, deep sclerotomy (EPNP) in open angle glaucoma surgeries.
The Glaucoma Implant Esnoper V2000 is a non-absorbable implant that gives a fixed permanent intrascleral space to facilitate aqueous humor.
This medical grade PMMA is designed for implantation between the corneal endothelium and the corneal graft in corneal transplant surgeries.
The Silicon Siobal Oil is high purity, free of low molecular weight components. It is a tamponade agent used in retinal detachment.
The AJL Pro + offers an design asymmetric in thickness and base width allowing the surgeon to choose the ring that is more idoneous for each patient depending on the keratometry values and the area it the ring will be implanted.
This medical grade PMMA Intracorneal Ring was designed to be implanted in the corneal stroma in corneal transplant surgeries.
This Vacuum Pump was designed to stabilize the cornea and facilitate the creation of corneal tunnels during the implantation surgery of intracorneal rings.
These Ferrara Ring Surgical Instruments were designed to stabilize the cornea and facilitate the creation of corneal tunnels during the implantation surgery of intracorneal rings.
The AJL BBG Ophtalmic Solution is a sterile brilliant G blue solution, non-pyrogenic, isotonic and ready to use in a vitroretinal surgery. The BBG solution can efficiently dye the internal limiting membranes (MLI).
These Ophthalmic Knives are available in several models and blade sizes for a ¨controlled cut¨, giving the surgeon the optimum quantity of tactile response necessary in procedures.
The PVA and Cellulose Eye Sponges are specifically designed for Lasik and other delicate procedures, The PVA and cellulose ocular spears are sterile, lint-free and very absorbent.
This Flexible Retractor of the Iris is made from a strong but flexible polypropylene to mechanically dilate the iris. Designed with vertical orientation for easy handling.
Sunglasses for Cataract Post-Surgery.
Download InformationSunglasses for Refractive Post-Surgery.
Download Information
These Ocular Protectors offer complete protection for post-cataract or Lasix patients. The polycarbonate gives maximum comfort and protection to post-surgery patients.
This kit offers complete protection for a post-cataract surgery.
These Ocular Protectors give post-Lasik surgery and cataract patients complete protection avoiding friction or pressure on the eye.
These Ophthalmology and Otorhinolaryngology Surgical Drapes are available for over the shoulders full range surgery. Halyard Health has flexible drape systems that offer better control of fluids and extra comfort to the patient in ophthalmic, neurological and other surgeries involving head and neck. Halyard drapes are designed to give you and your patients one less thing to worry about.
They include the following features:
Maximum resistance to flame.
Low lint generation to reduce risk of airborne bacterial transmission.
The eyedrapes are designed with a unique U shape fluid contention bag that helps reduce exposition during phacoemulsification and other fluid-intensive procedures and may also be used for left or right eye.
Product offerings include full or fenestrated incise.
These blue Patient Gowns are manufactured from SMS material for mayor protection providing complete coverage and preserving the patient´s privacy. Easy to put on and take off.
These sterile Surgeon Gowns are designed with 3 propylene layers (SMS) complying with AAMI 3 protection norms, raglan type sleeves for better movement, round collar and adjustable Velcro.
Download Information
Rexon-Eye is a non-invasive device that treats the cause of dry eye disease, providing long-term results for all forms of dry eye. It works by applying a high-frequency, low-power electrical current, capable of stimulating metabolism and natural regeneration of cells. This is a technology recommended and recognized worldwide by ophthalmologists and optometrists.